SmartRack 116 IP
User Guide
Zobrazit stránku 0
1 2 3 4 5 6 ... 66 67

Shrnutí obsahu

Strany 1 - User Guide

www.minicom.com International HQ Jerusalem, Israel Tel: + 972 2 535 9666 [email protected] North American HQ Linden, NJ, USA Tel: + 1 908 486 2

Strany 2 - Table of Contents

SMARTRACK 116 IP 9 Figure 2 Loosen 7 screws 3. Adjust the rear bracket to fit your cabinet, see below. Figure 3 Adjusting the bracket 4. Install the

Strany 3

USER GUIDE 10 Figure 5 Tightening the 7 screws 6. Repeat the steps above to connect the other rail to the other side of the rack. 7. Slide the Smar

Strany 4

SMARTRACK 116 IP 11 Figure 8 Connecting three flat screws to the rear of the console The console now sits snugly in the rack, see Figure 9. Figure 9

Strany 5 - 1. Welcome

USER GUIDE 12 Figure 11 Removing the six screws 2. Take the rear bracket out, see below. Figure 12 Taking the rear bracket out 3. Insert the long br

Strany 6 - 2. Introduction

SMARTRACK 116 IP 13 Figure 14 Connecting the bracket A to the sides of the Switch 2. Slide the Switch 116 IP into the rail and into the back of the

Strany 7 - 4. Hardware kit contents

USER GUIDE 14 7. The SmartRack Switch system configuration You connect servers to the 116IP switch via ROCs. Figure 17 illustrate the basic configura

Strany 8

SMARTRACK 116 IP 15 7.1.1 Connector table Connector Function Serial This port is for future Serial functionality Flash To update firmware of the a

Strany 9 - 6. Connecting to a rack

USER GUIDE 16 1. Connect the Mouse connector to the computer’s Mouse port. 2. Connect the Keyboard connector to the computer’s Keyboard port. 3. Conne

Strany 10 - Figure 2 Loosen 7 screws

SMARTRACK 116 IP 17 7.3 Connecting the CAT5 cables 1. Connect one connector to the ROC’s RJ45 port. 2. Connect the other connector to one of the Smart

Strany 11 - Figure 7 Rail–lock switch

USER GUIDE 18 Note! If a DHCP server later becomes available, the unit picks up the IP settings from DHCP server. To keep the static IP address, disab

Strany 12 - Figure 9 Console in the rack

SMARTRACK 116 IP 1 Table of Contents 1. Welcome...

Strany 13 - 6 Connecting to a rack

SMARTRACK 116 IP 19 IP address is assigned by the DHCP serverYesUnit boots upTo access the configuration page of the unit, open IE 6.0 or higher and t

Strany 14

USER GUIDE 20 10. Logging into the Web interface Client computer operating system. Windows 2000 or higher, with Internet Explorer 6.0 or later version

Strany 15 - Figure 18 116IP Switch ports

SMARTRACK 116 IP 21 The first warning disappears upon first SmartRack 116 IP client installation, when Minicom’s root certificate is installed. 11. N

Strany 16 - Connector Function

USER GUIDE 22 11.2 KVM.net KVM.net is a centralized IP based system for secure control of servers and network devices, power and user administration i

Strany 17 - Figure 22 ROC USB

SMARTRACK 116 IP 23 12.1 SNMP Events table The table below list all events recorded. Event Text Code Comment "System Boot" 1010 Reported

Strany 18 - 8. Terminology

USER GUIDE 24 Event Text Code Comment Login is not successful because server is busy. 2040 Login is not successful because server is busy. CONF_USER

Strany 19 - 11.1 on page 21

SMARTRACK 116 IP 25 13. Administration > User Settings From the menu click User Settings, Figure 27 appears. Figure 27 User Settings On this page

Strany 20

USER GUIDE 26 13.1 Adding a user To add a user: 1. Click and type a name and a password. The password must be at least 6 characters – letters or num

Strany 21 - 10.1 SSL Certificate notes

SMARTRACK 116 IP 27 14. Administration > Switch Configuration Give the servers connected to the SmartRack 116 IP unique names, so that users access

Strany 22 - 11.1 LAN 1

USER GUIDE 28 Figure 29 User Targets Configuration 2. Select a user from the User drop-down menu. 3. Check the Target servers the user can access (

Strany 23 - 11.2 KVM.net

USER GUIDE 2 20. Saving changes and logging out...31 21. Starting a remote s

Strany 24

SMARTRACK 116 IP 29 Password Policy – You have the option of a standard or high security level of password. The table below shows the parameters of th

Strany 25

USER GUIDE 30 18. Maintenance > Firmware Upgrade Upgrade the SmartRack 116 IP firmware to take advantage of new features. Download the firmware fro

Strany 26 - Figure 27 User Settings

SMARTRACK 116 IP 31 Figure 33 Restore factory settings 2. Check the box if you want to preserve Network settings. 3. Click . 20. Saving changes and

Strany 27 - 13.4 Blocking a user

USER GUIDE 32 Figure 34 Select Run as administrator On first connection install the Minicom certificate and ActiveX control. You must login as an Ad

Strany 28

SMARTRACK 116 IP 33 On the remote console you have the following: Server Confirmation label – This confirms the identity of the current server accesse

Strany 29 - 16. Security > Settings

USER GUIDE 34 To hide the Toolbar, either: Double-click the SmartRack 116 IP System tray icon . Or Press F9. To display the Toolbar repeat the above

Strany 30

SMARTRACK 116 IP 35 Low - Select Low for high compression and 16 colors. Medium - Select medium for medium compression and 256 colors. Medium is reco

Strany 31 - 19. Restore Factory Settings

USER GUIDE 36 Figure 38 Manual Video Adjustments controls Brightness / Contrast - use the scales to adjust the brightness and contrast of the display

Strany 32

SMARTRACK 116 IP 37 21.6 Power cycle This button . is for future Serial power management options. 21.7 Keyboard key sequences Click . A list of defi

Strany 33

USER GUIDE 38 Figure 40 Add Special Key Dialog box 2. Give the key sequence a name in the Label field. 3. Click Start Recording. 4. Press the desire

Strany 34 - 21.2 The Toolbar

SMARTRACK 116 IP 3 25.4.3 Updating the firmware...

Strany 35

SMARTRACK 116 IP 39 21.8.1 Aligning the mice pointers When accessing the Target Server, the mice may appear at a distance to each other. To align the

Strany 36

USER GUIDE 40 Figure 41 Mouse Settings Dialog box 2. Select the Target Server’s Operating System and click OK. Instructions and sliders appear. 3. Fo

Strany 37

SMARTRACK 116 IP 41 Figure 42 Mouse Emulation Dialog box Select the mouse connected to the Local Console port on the SmartRack 116 IP, e.g. if the lo

Strany 38 - 21.7 Keyboard key sequences

USER GUIDE 42 Full Screen Mode - Check this option to make the remote session screen appear in full screen mode from the next reconnection onwards. To

Strany 39

SMARTRACK 116 IP 43 22.1 Entering Safe mode To enter Safe mode: 1. Press and hold down the Local button for 3-4 seconds and at the same time power up

Strany 40

USER GUIDE 44 Figure 45 Login page 4. Type username: admin , password: SAFEmode. (Case sensitive). (This username and password works only in Safe mod

Strany 41 - Go to the Mouse settings

SMARTRACK 116 IP 45 Figure 48 Warning 3. Click OK, the factory defaults are restored. When the process finishes Figure 49 appears. Figure 49 Reboot

Strany 42

USER GUIDE 46 Section II Section II explains how to operate the SmartRack 116 IP Switching system locally (sections 23 and 24) and how to upgrade th

Strany 43 - 21.10 Full screen mode

SMARTRACK 116 IP 47 Port numberappears hereInstructionkeysC=computer Figure 51 OSD Main window 24.1.1 Navigating the OSD To navigate up and down use

Strany 44 - 22.1 Entering Safe mode

USER GUIDE 48 Note! When the OSD is password protected (explained below) only the Administrator has access to the F2 settings window. 24.1.4 The Gener

Strany 45 - Figure 47 Warning

USER GUIDE 4 1. Welcome Thank you for buying the SmartRack 116 IP system. This system is produced by Minicom Advanced Systems Limited. This document p

Strany 46 - Figure 50 Reboot

SMARTRACK 116 IP 49 24.1.4.4 User (Status U) There are 6 different Users in the SmartRack 116 IP system. Each User has a Profile set by the Administr

Strany 47 - 24. The OSD

USER GUIDE 50 24.1.4.8 Changing the Keyboard language In the OSD the names of the computers can be written in 3 different languages – English (EN), G

Strany 48 - Figure 52 Settings window

SMARTRACK 116 IP 51 To erase an entire line: Place the cursor at the beginning of the line. Keep the Spacebar depressed until the line is erased. 24.1

Strany 49 - 24.1.4.1 Security

USER GUIDE 52 2. Place the cursor over one of the 3 digits and type a new number. Enter a leading zero where necessary. For example, type 040 for 40 s

Strany 50 - 24.1.4.7 Serial port

SMARTRACK 116 IP 53 24.1.9 Security In the Settings window navigate to the Security line and press Enter. The Security settings window appears see Fig

Strany 51

USER GUIDE 54 Figure 58 HELP window Please note! All the functions set out in the Help window are performed from the Main window. The Help window is

Strany 52 - 24.1.6.2 Keyboard (KB)

SMARTRACK 116 IP 55 Note! Picture quality is relative to distance. The further away a remote computer is from the SmartRack 116 IP, the lower the imag

Strany 53

USER GUIDE 56 25. Upgrading the SmartRack 116 IP firmware With the Update software program you can upgrade the firmware for the: • 116 IP Switch •

Strany 54

SMARTRACK 116 IP 57 MINICOMMINICOMROCsto serversUpdate software installed hereTo Flash connectorRS232 Download cable1 2 3 4 5 6 7 810 11 12 13 14 15 1

Strany 55 - Figure 58 HELP window

USER GUIDE 58 The table below explains the functions of the buttons and boxes in the SmartRack 116 IP Switch Update window. Button or Box Function S

Strany 56

SMARTRACK 116 IP 5 Section I This section explains how to configure and operate the SmartRack 116 IP system remotely over IP. Section II on page 46, e

Strany 57 - 25.4.4 on page 60

SMARTRACK 116 IP 59 2. Click . The version numbers appear in the Switch box. 3. Click . The switch hardware version number appears in the Switch

Strany 58 - Figure 60 Update window

USER GUIDE 60 Figure 62 Open box 4. Open the file. 5. Click Start. The SmartRack 116 IP Switch Update flashes the firmware. On completion the firmw

Strany 59 - 25.4.1.1 OSD version number

SMARTRACK 116 IP 61 25.5.1 Resetting through the Update software Reset the SmartRack 116 IP Manager or ROCs when for example the unit hangs or when th

Strany 60 - 25.4.1.2 ROC version number

USER GUIDE 62 If the electricity fails during the firmware update of the ROCs a Not Responding or Upgrade Error message appears. Restart the upgrade f

Strany 61 - Figure 62 Open box

SMARTRACK 116 IP 63 26. Technical specifications Operating systems Target server Windows, Linux, UNIX and other major operating systems Client compu

Strany 62

USER GUIDE 64 Brightness White 250cd/m2 Back light Four lamps Supported colors 16.7M Keyboard / mouse 106 key PS/2 keyboard with touchpad Sync 4

Strany 63

SMARTRACK 116 IP 65 27. Video resolution and refresh rates Hz → 56 60 65 66 70 72 73 75 640x480 x x x x x 720x400 x

Strany 64 - 26. Technical specifications

USER GUIDE 66 Regional Offices Germany Kiel Tel: + 49 431 668 7933 [email protected] France Vincennes Tel: + 33 1 49 57 00 00 info.france@mini

Strany 65 - ROC PS/2 ROC USB

USER GUIDE 6 Web-based control - Browser control to a target server, from any location via secured standard IP connection. Multi-user view mode - All

Strany 66 - 30. WEEE compliance

SMARTRACK 116 IP 7 Long bracket x 2. (For increased rack depth of 905 ~ 990mm) Short bracket x 2 Bracket attachment x 2 Note! The short bracket

Strany 67

USER GUIDE 8 5.1 Avoiding general rack mounting problems Elevated operating ambient temperature The operating ambient temperature of the rack environ